EXAMINATION OF AN ESCALATOR OR MOVING WALKWAY Client Owner/Site Client Number: 493 SYSTEM TEST Test Location 1 (workshop) Report Number: 1789033677 C/O Tony Dover C/O Tony Dover, 11 Defender Court Item Ref: 28563 11 Defender Court Sunderland Date of Examination: 10-09-2026 Sunderland SR5 3PE SR5 3PE Item description Belt Sling Location on site workshop Manufacturer Year Sealey Model Serial Number Asset ID Eye13 Examination Frequency 6 Months 10-09-2026 1/3 1789033677/28563/5011 Plant details Location of plant if different from site address - Any further details Down direction only Date of construction or reconstruction 1996 Examination Type of examination Thorough out of service & in service. (visit by Kone Engineer, John Curtis) Maintenance Access and guarding Yes Running condition Yes Emergency stop switches and electrical safety devices Yes Mechanical safety devices Yes Electrical equipment (including earth continuity) Yes Braking system(s) Yes Treadway, steps and pallets (gaps between) Yes Comb plate and terminal guides (gaps between) No - One upper entry comb plate tooth is broken, comb plate should be replaced. One lower exit comb plate tooth is partially broken, comb plate should be replaced. Skirt deflector devices and balustrades (gaps between steps and skirting) Yes Surrounds, lighting and warning/advisory signs Yes Handrails Yes Overspeed governor Yes Drive system: worm or spur gearing Yes Controller No - The missing electrical controller lock should be replaced. Not checked tank covers, not removed. What parts (if any) were inaccessible? Those remote & under covers not removed. Internals of gearbox. Defects and repairs Are there any defects which give rise to imminent danger and require No attention immediately? Are there any defects which could, in time, give rise to danger and require No attention within the specified time period? Are there any general defects? Yes - Yes The oil drips on the steps, steps should be cleaned. Other observations For guidance only approximate clearances, as determined by measurement were: 10-09-2026 2/3 1789033677/28563/5011 Step to Step: 3 mm max. Step to Skirting: 4 mm and 3 mm max total 7 mm. Bottom Step to Comb plate: 4 mm. Top Step to Comb plate: 4 mm. PASS I certify that the above equipment was thoroughly examined (unless otherwise stated) and, subject to any remedial action to defects noted on this report, which are or could become a danger to persons, the equipment is safe to operate. Date of last Examination (if known):24-08-2026 Latest date by which the next examination must be carried out:10-03-2027 Examined by: ABRM Test Engineer Contract Number: ALANBOSWELL.ENREP.CO.UK-493-07 Qualification: TESTER Engineer LIVE Date of making this record: 10-09-2026 Alan Boswell Risk Management Ltd, Prospect House, Rouen Road, Norwich, NR1 1RE, Registered in England & Wales, Company Number: 10-09-2026 3/3 1789033677/28563/5011